XL650 Primers Flipping

Oct 3rd, 2016

The most likely causes for primers to flip when seating are either the primer seating assembly is not threaded fully up into the underside of the platform, or the station 2 locator tab is not adjusted to be within .002-.004" of touching the case.

If primers flip in the tube, then the primer that flipped was likely out of round.

If you need further assistance please call us at 800-762-3845.  For the best possible customer service please make sure you are in front of your machine when you call.

We have several helpful videos on our site.  Just scroll down until you find the one you need.